M5、3-position 5-way valve width 10mm、Single electronic control、Middle leakage、FAS-B10-P53E-Z、8100810050

M5、3-position 5-way valve width 10mm、Single electronic control、Middle leakage、FAS-B10-P53E-Z、8100810050

Ordering code: 8100810050
Part number : FAS-B10-P53E-Z
  • Function: 3/2C, 3/2U 2x3/2C, 2x3/2U, 2x3/2H 5/2-way valve, single solenoid control 5/2-way valve, double solenoid control 5/3C, 5/3U, 5/3E
  • Valve width: 10 mm
  • Flow rate: 130…300 l/min
  • Working voltage: 24 V DC

Related recommendations

  • Function Parameter
  • Resource Download
  • Related accessories
TypePlate valve M5
3-position 5-way valveExternal pilot
IllustrateMiddle leakage
Ordering code8100810050
Part numberFAS-B10-P53E-Z



Main technical parameters

Valve functionT32-AT32-MM32-RB52M52-RP53
Normal positionC1)U2)H4)C1)U2)H4)C1)U2)--C1)U2)E3)
Stable positionSingle electronic controlDual electronic controlSingle electronic control
Reset method: air resetYesNoNo-Yes5)-
Reset method: mechanical spring resetNoYesYes-Yes5)-
Air port 1 vacuum operationNoWhen only external pilot is used
DesignPiston slide valve
Sealing principleSoft
Drive modeElectric
Control methodPilot
Pilot air sourceExternal
Exhaust functionWith flow control
Switch position displayLED
Standard rated flow, M5/M7 [l/min]160
140140300300260
Flow rate on manifold plate, M5, front [l/min]150130130220220200
Flow rate on manifold plate, M7, front [l/min]160140140270270250
Flow rate on manifold plate, M7, bottom [l/min]160140140300300260
Valve width [mm]10
Air port    1, 3, 5, 12/14, 82/84On the manifold board
Air port     2, 4On the manifold board
Product weight [g]59605358
Certificationc UL us - Certification (OL)
CE marking (see Declaration of Conformity)Comply with EU EMC directive
Corrosion resistance grade CRC2

Electrical parameters
Electrical connectionDrop-in type
Operating voltage [V DC]24±10%
Power consumption per solenoid coil [W]1/0.4 (after 25ms)
Continuous power rate ED [%]100
Maximum switching frequency [Hz]3
Protection class according to EN 60529Standard protection grade is IP40, protection grade is IP67, with D-SUB and IO-Link interface)

1)C= Normally closed/mid-closed type

2) U=normally open/medium voltage type

3)E= Middle leakage type

4)H=2x 2-position 3-way valve integrated in one housing, 1 x normally closed and 1 x normally open 5)Hybrid reset method


Working and environmental conditions
Valve functionT32-A1)T32-M2)M32B52M52-M2)P53
Working mediumCompressed air according to ISO 8573-1:2010 [7:4:4]
Operating pressure Internal pilot air supply [bar]1.5 … 82.5 … 82.5 … 81.5 … 83 … 83 … 8
Operating pressure external pilot [bar]1.5 … 10–0.9 … 10–0.9 …8–0.9 … 10
Pilot pressure4) [bar]1.5 … 82 … 82 … 81.5 … 83 … 8
Ambient temperature [°C] –5 … +60
Medium temperature [°C] –5 … +60

Valve switching time
Valve functionT32-A1) T32-M2) M32 B52 M52-M 2)P53
Valve function81010-1212
Switching time, off [ms]

20

2020-3038
Conversion time [ms]---9-16

1) Air reset

2) Mechanical spring return