G1/8、2x 2-position 3-way valve、Gas reset、Valve width 14 mm、FV-L14-32H-AZT-G18、566507

G1/8、2x 2-position 3-way valve、Gas reset、Valve width 14 mm、FV-L14-32H-AZT-G18、566507

Ordering code: 566507
Part number : FV-L14-32H-AZT-G18
  • Function: 2x3/2C, 2x3/2U, 2x3/2H 5/2-way valve, single solenoid control; 5/2-way valve, double solenoid control 5/3C, 5/3U, 5/3E
  • Valve width: 14 mm
  • Flow rate: 480…730 l/min
  • Operating voltage: 5, 12 and 24 V DC
Collect 询盘

Related recommendations

  • Function Parameter
  • Resource Download
  • Related videos
TypeIn-line valve G1/8
2x 2-position 3-way valveExternal pilot
Illustrate1x normally open, 1x normally closed, reset method: air reset


Main technical parameters

Valve function32-A32-MM52B52P53
Normal positionC1)P2)H4)C1)P2)C1)--C1)P2)E3)
Stable positionSingle electronic controlDual electronic control
Reset method: air resetYesNoYes-No
Reset method: mechanical spring resetNoYesNo-Yes
Air port 1 vacuum operationNoWhen only external pilot is used
DesignPiston slide valve
Sealing principleSoft
Drive modeElectric
Control methodPilot
Pilot air sourceInternal or external
Exhaust functionWith flow control
Nominal diameter [mm]4.64.35.6
Rated flow [l/min]650600650550500500730780650600
Flow rate on manifold board [l/min]620580520480480680730620
580
Switching time on/off [m s]8/2311/15
14/22-12/40
Conversion time [m s]-820
Valve width [mm]14
Air port   1, 2, 3, 4,5G1/8
Air port   12/14M5
Product weight [g]8980788989

1) C=Normally closed/mid-closed type

2) P=Normally open/medium pressure type

3) E=Mid-discharge type

4) H=2x 3/2-way valve integrated in one housing, 1 x normally closed and 1 x normally open


Electrical parameters
Working voltage [V DC]5, 12 and 24 ±10%
Power [W]1,By reducing the holding current function to 0.35
Continuous power rate ED [%]100
Protection class according to EN 60529IP40 (with socket), IP65 (for M8)

Working and environmental conditions
Valve function32-A1)32-M2)M522)B52P53
Working mediumCompressed air according to ISO 8573-2010 [7:4:4]
Work pressure  Internal pilot [bar]1.5 … 83.5 … 82.5 … 81.5 … 8
Work pressure  External pilot [bar]1.5 … 10–0.9 … 10–0.9 … 10
Pilot pressure3[bar] 1.5 … 82 … 82.5 … 81.5 … 83 … 8
Ambient temperature  [°C]–5 … +50, –5 … +60, with holding current reduction function
Medium temperature  [°C]–5 … +50, –5 … +60, with holding current reduction function

1) Air reset