Ethernet interface、Support Modbus-RTU communication protocol、Drives 24 dual solenoid valves、CTEU-MBR-16、007F22

Ethernet interface、Support Modbus-RTU communication protocol、Drives 24 dual solenoid valves、CTEU-MBR-16、007F22

Ordering code: 007F22
Part number : CTEU-MBR-16
  • Power interface: M12, male, 4-pin, A-coded;
  • Communication interface: M12, female, 4-pin, D-coded; M12, female, 4-pin, D-coded;
  • Supports Modbus-RTU communication protocol and drives up to 24 dual solenoid valves

Related recommendations

  • Function Parameter
  • Resource Download
  • Related accessories

Main technical parameters

Size W x L x H  [mm]105.6 x 50 x 39
Fieldbus interface2x M12 socket, 4-pin
Working voltage range  [V DC]18 -30.2
Maximum power  [A]4
Maximum number of solenoid coils48
Maximum number of valves24
Product weight   [g]85
Cable length  [m]100
Housing materialReinforced polyamide
Material considerationsRoHS compliant



Pin assignment IO-Link

Pin assignment for power connectionPinDistributeIllustrate

4P.png

124VLoad power (valve/output)
20VLoad power (valve/output)
324VOperating power supply (electronic components, sensors/inputs)
40VOperating power supply (electronic components, sensors/inputs)